AMS ENTERPRISESINTERIOR & ELECTRICAL CONTRACTOR
CLASS 'A' ELECTRICAL & TURNKEY INTERIOR EPC
Full Statutory & NBC 2016 Compliance

Our Comprehensive Services

Single-source turnkey EPC accountability spanning high-precision architectural joinery, licensed Class 'A' heavy electrical infrastructure, automated life-safety, and round-the-clock facility maintenance.

100%IN-HOUSE EPCZero sub-tier delay
Class 'A'LICENSEDCEA & DISCOM signoff
1.8M+SQ. FT. DONETurnkey delivered
DIVISION 01 // SPATIAL & ARCHITECTURALTURNKEY SCOPE

Interior Solutions & Custom Millwork

Precision joinery, modular acoustic workstations, and architectural acoustics engineered for resilient banking halls and agile corporate workplaces.

Enquire for Interior Works
Flagship Retail Banking Installation with Modular Teller Stations
FLAGSHIP RETAIL BANKING INSTALLATION

Modular Teller Stations with Integrated Low-Voltage Raceway

Technical Specification MatrixIS: 2062 & EN 13964
  • Joinery Substrates: BWP Grade Marine Plywood (IS 710) with 1.0mm anti-fingerprint laminates and CNC-milled natural oak slats.
  • Acoustic Ceilings: NRC 0.85 mineral fiber baffles and Saint-Gobain Gyproc moisture-resistant seamless perimeter drywall.
  • Commercial Flooring: Heavy duty Class 33 rated woven vinyl, 800×1600mm vitrified tiles, and anti-static server room access flooring.
  • Glazing Systems: 12mm toughened frameless glass partitions with DORMA hardware and acoustic double-glazed mullions.
STANDARD DELIVERY TURNAROUND45 to 60 Calendar Days for typical 5,000–12,000 Sq. Ft. commercial fit-outs.

Space Planning & 3D BIM

Ergonomic human circulation mapping, heat-load spatial orientation, and 3D architectural renders.

CORE DELIVERABLESDetailed BOQs, MEP Clash Coordination, Revit BIM Renders

Modular Furniture & Joinery

Bespoke banking cash counters, executive manager suites, ergonomic benching, and acoustic privacy pods.

CORE DELIVERABLESFactory-fabricated carcasses, Corian solid surfaces, integrated wire channels

False Ceiling & Acoustics

Seamless Gypsum board suspended grids, Armstrong acoustic ceiling tiles, metal baffles, and perimeter coves.

CORE DELIVERABLESGI framing (0.55mm BMT), acoustic insulation pads, flush shadow-line trims

Floor Finishes & Subflooring

Precision leveling, Italian marble diamond polishing, anti-static vinyl rolls, and modular nylon carpet tiles.

CORE DELIVERABLESMoisture barrier screeds, epoxy expansion joints, underfloor access pedestals

Partition Engineering

Floor-to-ceiling 12mm toughened glass walls, STC-45 acoustic drywall partitions, and demountable aluminum systems.

CORE DELIVERABLESSound attenuation batts, hydraulic patch fittings, customized frosted film

Live-Site Branch Renovation

Phased overnight retrofitting for operating commercial centers and bank branches with zero business downtime.

CORE DELIVERABLESDust partition enclosures, weekend fast-track handovers, zero punch-list
DIVISION 02 // ELECTRIFICATION & POWERGOVT. LICENSED 'A' GRADE

Heavy Electrical & Power Infrastructure

Certified high & low tension power execution from sub-station transformer yards to high-density clean UPS circuits and Central Electricity Authority (CEA) licensing.

Enquire for Electrical Works
LICENSED CLASS 'A' ELECTRICAL CONTRACTING CREDENTIALS

Full-Spectrum Statutory Compliance & Load Approvals

AMS Enterprises manages the complete electrification lifecycle: Single Line Diagram (SLD) engineering, CEA statutory approvals, transformer substations up to 2500 kVA, automatic transfer switches (ATS), sandwich busbar trunking (BBT), and copper earth-grid stabilization with certified <1.0 Ohm resistance.

IS 732 Wiring StandardIS 694 FRLS Copper ConductorsIEC 61439 Switchboard SpecCEA Inspectorate Approved
APPROVED SWITCHGEAR & CABLE PARTNERS
Schneider ElectricAir Circuit Breakers (ACB) & APFC Relays
Legrand / ABBMCCBs, MCBs & Modular Distribution Boards
Polycab & HavellsFRLS-H Armoured Cables & Heavy LT Runs
L&T ElectricalCustom Fabricated Main Switchboards
Insulation & Thermography:Megger 1000V Certified
CODE: EC-01

Conduit & Heavy Cabling

Precision recessed and surface MS/PVC conduit networks with separate color-coded neutrals and earth wires to prevent harmonic crosstalk.

IS 9537 MS Conduit Rigidity
CODE: EC-02

HT/LT Switchboards & BBT

Fabrication of Form-4 type-tested LT panels, busbar trunking up to 4000A, and capacitor banks with automated power factor control (APFC > 0.98).

Form-4 Enclosures (IP54/IP55)
CODE: EC-03

Architectural Illumination

Glare-free UGR<19 recessed linear fixtures, DALI-2 dimmable controls, perimeter cove accents, and high-mast industrial floodlights.

450-500 Lux Uniform Banking Floor
CODE: EC-04

Megger Testing & CEA Audits

Complete earth resistance validation (<1.0 Ohm), phase-balance thermography, insulation resistance logs, and official inspectorate liaisoning.

Certified Statutory Handover Pack
DIVISION 03 // LIFE SAFETY & LOSS PREVENTIONFIRE & SECURITY

Integrated Safety, CCTV & Access Controls

RBI-compliant surveillance matrixes, addressable fire early-warning setups, and biometric multi-tier entry gateways for maximum asset protection.

Enquire for Security Systems

CCTV IP Surveillance

High-definition IP surveillance with AI analytics, 90-day redundant NVR storage arrays, ATM cash-shutter monitoring, and remote SOC cloud integration.

4K Starlight low-light clarity
Automated perimeter tampering alerts
Banking RBI-mandated 90-day retention
STANDARD HARDWAREHikvision Enterprise, Honeywell, CP Plus Pro

Fire Detection & Suppression

Microprocessor-based addressable fire alarm panels, photoelectric smoke sensors, clean-agent (FK-5-1-12/NOVEC) flooding for server rooms, and manual call points.

NBC 2016 Part 4 Life Safety Compliance
Server Room Gas Suppression Integration
Integrated Audio Hooters & Strobe Beacons
APPROVAL STANDARDUL-Listed, FM Approved, Local CFO Fire NOC

Access Control & Locks

Heavy-duty magnetic electromagnetic locks (600/1200 lbs hold), touchless biometric facial recognition, interlocking mantrap vestibules, and time attendance logs.

Two-man rule vault interlocking doors
Encrypted RFID & Mobile NFC credentials
Emergency breakaway integration with Fire Alarm
SYSTEM PROTOCOLWiegand / OSDP v2 encrypted communication
DIVISION 05 // ASSET LIFECYCLE & SLA MANAGEMENT24/7 RAPID RESPONSE

Annual Maintenance Contracts (AMC)

Proactive preventative thermography audits, battery health testing, and contractual 4-hour SLA breakdown response guaranteeing 99.9% uptime.

Enquire for AMC Plan
QUARTERLY CYCLEAMC-ELEC

Preventative Thermography Audits

FLIR infrared thermal scans of all switchgear, busbars, and distribution boards to detect loose crimping, harmonic overloads, and fire risks before outages happen.

Earth pit resistance verification (<1.0 Ohm)
Busbar bolt torque & contactor calibration
Total Harmonic Distortion (THD) reporting
DELIVERABLEDigital IR Thermal Heat-Map & NOC
MONTHLY & ON-CALLAMC-PWR

UPS & DG Power Maintenance

Full-scope maintenance of online double-conversion UPS systems, internal SMF battery bank impedance diagnostics, and auto-mains failure (AMF) synchronization.

Individual cell voltage & load bank discharge test
UPS capacitor bank & cooling fan checks
Emergency mobile bypass unit mobilization
DELIVERABLEMonthly Battery Health Status & Uptime Log
CONTINUOUS OPERATIONSAMC-FITOUT

Interior Joinery & Hardware Care

Preventative upkeep of architectural assets: hydraulic floor springs, access door lock alignment, acoustic ceiling grid re-leveling, and touch-up wood varnishing.

DORMA glass door alignment & hydraulic damping
Workstation drawer tracks, locks & modesty panels
Carpet deep extraction and raised access floor leveling
DELIVERABLEQuarterly Facility Snag Audit & Technicians
STANDARD CONTRACTING PROTOCOL

Guaranteed Service Level Agreement (SLA) Matrix

24/7 Central Dispatch Desk Active
INCIDENT TIERCLASSIFICATION SCOPEEMERGENCY RESPONSERESOLUTION WINDOWDEDICATED PERSONNEL
Tier 1: Critical Blackout
Complete facility power outage, Main LT Panel trip, transformer fault, server UPS shutdown.≤ 60 Minutes4 Hours (Bypass Mode)Senior Electrical Engineer + Mobile Van
Tier 2: Degradation
Partial branch lighting outage, single phase dip, server room precision AC alarm, camera outage.≤ 2 Hours8 Hours Complete FixLicensed MEP Field Electrician
Tier 3: Routine Snag
Door lock realignment, ceiling acoustic tile replacement, carpet touch-up, extra power socket.≤ 24 Hours48 HoursGeneral Joinery & Line Technician
INTERACTIVE SCOPE ASSESSMENT

Estimate Your Turnkey Project Requirements

Configure your space parameters and desired scope to view standard deliverables and rapid timeline estimates.

4,500 Sq. Ft.
1,000 Sq. Ft.12,500 Sq. Ft.25,000 Sq. Ft.
Turnkey Interior & JoineryAcoustic ceilings, millwork & glazing
Class 'A' Heavy ElectricalHT/LT panels, busbar & cabling
Fire & CCTV AutomationGas suppression & IP biometric matrix
1-Year Facility AMC CoveragePreventative thermography & SLAs
ESTIMATED TURNKEY SCOPEAlgorithm v2.4
Target Completion Timeline:
53 - 66 Calendar Days
Guaranteed milestone-based fast-track execution
Calculated Connected Load:54 kVA - 81 kVA
Workstation Capacity:47 - 60 Desks
Statutory Approval Pack:Included (CEA & Fire NOC)
Submit Specs for Formal RFP

Guaranteed official tender BOQ within 48 business hours.

START YOUR TURNKEY FIT-OUT WITH CERTAINTY

Partner with India’s Premier Interior & Electrical EPC Specialist

Consult directly with our licensed electrical engineers and turnkey project leads. Complete tender documents, single-line diagrams, and BOQs delivered on schedule.